Fuel Cell Test Station PTS-10
Key features
- Suitable for low-temperature PEM fuel cells
- Convenient testing of short stacks or large-area single cells
- Automatic control of flow rate, humidity, temperature and back pressure individually for anode and cathode lines
- Variety of electronic loads and potentiostats available
- Cell/stack temperature control with liquid cooling circuit
- Robust system based on industrial PLC with data logging into SQL database
- Safety features for fully automated operation
- CE certificate of conformity
Applications
Ideally suited for research and development of large-area single cells or verification of stack design on short-stack level. Well-defined and repeatable conditions of Leancat PTS-10 enable benchmarking of fuel cells also thanks to extensive scripting possibilities.
Specifications
Power range:
100 W…1 kW
Fuel flow-rate range:
0.25…25 Nl/min
Dew-point temperature range:
up to 95 °C
Liquid cooling
of cell/stack:
up to 95 °C
(increase to 120 °C possible)
enables cell/stack pre-heating
Cell Voltage Monitoring:
Customizable number of channels
Max. current:
1200 A
Oxidant flow-rate range:
0.9…90 Nl/min
Gas pre-heating temperature range:
up to 120 °C
Back-pressure control range:
up to 4 bar(g)
Options:
Zero-voltage load, potentiostat with EIS, dead-end mode, introduction of contaminants and other customizations